For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).
Compact unit suitable for wall mounting or fixation on the floor.

Applications

  • Desalination of softened water
  • Suitable for all commercial and industrial applications
  • Ideal for medical practices or other public locations with visitors

Features

• Wall mounted or free standing
• Particularly space-saving (400 x 340 x 1190 mm)
• RO Digital controller
• Recovery from 75% to 80%
• Salt rejection percentage: min. 97%
• Working pressure: 12 bar
• Voltage: 230 V/50 Hz
• Digital flow meters

General Conditions for Installation

The unit may only be used for the desalination of softened feed water of drinking water quality or appropriately pretreated well or surface water. The unit is designed for a salinity (TDS) of 1,000 mg/l and a temperature of 15 °C. Under
these conditions, the projected permeate output is achieved even after three years of operation. The permeate yield depends on the raw water quality and the pre-treatment. The following parameters must be maintained in the feed water:

  • Free chlorine not detectable
  • Iron (Fe) < 0.2 mg/l
  • Manganese (Mn) < 0.05 mg/l
  • Silica (SiO2) < 25 mg/l
  • Silt density index (SDI) < 3
  • Feed water temperature 5 – 35 °C
  • Feed water pressure 3 – 6 bar
  • Pressure fluctuation ± 0.5 bar
- +

Item Name          Permeate Flow L/H           Membranes

UO-D 120            120                                        4021 x1

UO-D 300            300                                       4040 x 1

UO-D 500            500                                       4040 x 2