Fleck Birm Filter

£536.40£6,395.50

Clear

Description

General

General conditions for installation
Connection Inlet & Outlet 2510 / 2750 : 1” BSP
2850 : 1½” BSP
3150 : 2” BSP
Electrical Rating : 230-24V / 50 Hz
Power Rating : 55 watts
Minimum Inlet Pressure : 200 kPa ( 2 Bar )
Maximum Inlet Pressure : 700 kPa ( 7 Bar )
Vacuum : Not permitted
Average Pressure Loss : 100 kPa ( 1 Bar )
Maximum Water Temperature : 43ºc
Operating Conditions : Dissolved Oxygen (DO) content must be equal to
at least 15% of the iron (or iron and manganese) content.

Media Type : Birm
Life Span : Dependent on frequency of backwashing and site conditions

Model Reference Valve H1 Vessel H2 Vessel B1 Filter Ht Inlet/Outlet Drawing No
FLF25C10BR 220 1387 257 1607 1″ Fig. 1
FLF25C13BR 220 1374 334 1594 1″ Fig. 1
FLF25C14BR 220 1660 369 1880 1″ Fig. 1
FLF25C16BR 220 1660 406 1880 1″ Fig. 1
FLF27C18BR 220 1750 469 1970 1″ Fig. 1
FLF28C21BR 220 1640 552 1860 11/2″ Fig. 1
FLF31C24BR 200 2230 610 2430 1″ Fig. 2
FLF31C30BR 200 2300 770 2500 2″ Fig. 2
FLF31C36BR 200 2350 927 2550 2″ Fig. 2
FLF31C42BR 200 2435 1074 2635 2″ Fig. 2

Regeneration

Start: Programmable regeneration time + day interval
Manual: Manual operation as required

Operating Conditions
For organic and colour removal 6 mins contact time
For dechlorination 3 mins contact time. (Flow rates may be doubled)

Specification

Specification
Vessel Diameter 10″ 13″ 14″ 16″ 18″
Media Volume cu ft 1 2.5 3 5
Service flow rate rn3/hr 0.6 1.1 1.2 1.5 1.9
Backwash flow rate m3/hr 1.2 2.3 2.4 3.2 4.1
Vessel Diameter 21″ 24″ 30″ 36″ 42″
Media Volume Cu ft 6 8 14 20 28
Service flow rate m2/hr 2.6 3.5 5.4 7.8 10.7
Backwash flow rate m3/hr 5.2 7.3 11.4 16.4 22.3